Absolute Encoders Single turn
Singleturn and multiturn encoders with Fieldbus, SSI,
parallel- or analogue interfaces
Technologies
-
Absolute multiturn encoders with mechanical gear or
electronic multiturn stage
-
Intelligent Sensing Technology (IST)®
-
Integrative Technology®
-
Safety LockTM Design, OptoASIC Technology
-
Latest field bus profile
|
Miniature 2450
(Shaft), 2470 (Hollow shaft)
Shaft/Hollow shaft Ø: |
Ø 6/ 1/4" / 8 / 10 mm |
Housing diam.: |
Ø 36x42 |
Speed: |
6.000 U/min |
Operating temp.: |
-40°C ... +85°C |
Protection: |
IP 69k |
Type of Connection: |
Cable or Plug |
Resolution: |
512 (9 Bit) |
Interface: |
SSI |
Supply voltage DC: |
5...30 V |
Optional: |
EX approval for hazardous areas 2/22
Sea-water
resistant |
more... |
|
|
|
Sendix absolut 3651
(Shaft), 3671 (Hollow shaft)
Shaft/Hollow shaft Ø: |
Ø 6/ 1/4" / 8 / 10 mm |
Housing diam.: |
Ø 36x42 |
Speed: |
6.000 U/min |
Operating temp.: |
-40°C ... +85°C |
Protection: |
IP 69k |
Type of Connection: |
Cable or Plug |
Resolution: |
4096 (12 Bit) |
Interface: |
analog, 0...10 V, 4...20 mA
|
Supply voltage DC: |
18...30 V |
Optional: |
EX approval for hazardous areas 2/22
Sea-water
resistant |
more... |
|
|
|
Sendix absolut F3653
(Shaft), F3673 (Hollow shaft)
Shaft/Hollow shaft Ø: |
Ø 6/ 1/4" / 8 / 10 mm |
Housing diam.: |
Ø 36x42 |
Speed: |
12.000 U/min |
Operating temp.: |
-40°C ... +90°C |
Protection: |
IP 67 |
Type of Connection: |
Cable or M12-Plug |
Resolution: |
17 Bit |
Interface: |
SSI, BiSS |
Supply voltage DC: |
5 V or 10...30 V |
Optional: |
EX approval for hazardous areas 2/22 |
more... |
|
|
|
Sendix absolut F3658
(Shaft), F3678 (Hollow shaft)
Shaft/Hollow shaft Ø: |
Ø 6/ 1/4" / 8 / 10 mm |
Housing diam.: |
Ø 36x42 |
Speed: |
12.000 U/min |
Operating temp.: |
-40°C ... +85°C |
Protection: |
IP 67 |
Type of Connection: |
Kabel |
Resolution: |
16 Bit |
Interface: |
CANopen |
Supply voltage DC: |
10...30 V |
Optional: |
EX approval for hazardous areas 2/22 |
more... |
|
|
|
Sendix absolut M3658
(Shaft), M3678 (Hollow shaft)
Shaft/Hollow shaft Ø: |
Ø 6/ 1/4" / 8 mm |
Housing diam.: |
Ø 36x42 |
Speed: |
6.000 U/min |
Operating temp.: |
-40°C ... +85°C |
Protection: |
IP 69k |
Type of Connection: |
Cable or Plug |
Resolution: |
16384 (14 Bit), skalierbar
|
Interface: |
CANopen, SAE J1939 |
Supply voltage DC: |
5...30 V |
Optional: |
EX approval for hazardous areas 2/22
Sea-water
resistant |
more... |
|
|
|
Sendix absolut 5853
(Shaft), 5873 (Hollow shaft)
Shaft/Hollow shaft Ø: |
Ø 6/10/ 1/4" / 3/8" /15 mm
|
Housing diam.: |
Ø 58x38 |
Speed: |
12.000 U/min |
Operating temp.: |
-40°C ... +90°C |
Protection: |
IP 67 |
Type of Connection: |
Cable or Plug |
Resolution: |
max. 131072 (17 Bit) |
Interface: |
SSI or BISS, + incremental track
(sinus/cosinus or TTL) |
Supply voltage DC |
5 V or 10...30 V |
Optional: |
EX approval for hazardous areas 2/22
Sea-water
resistant |
more... |
|
|
|
Universal 5850
(Shaft), 5870 (Hollow shaft)
Shaft/Hollow shaft Ø: |
Ø 6/8/10/12 mm |
Housing diam.: |
Ø 58x66 |
Speed: |
12.000 U/min or 6.000 U/min
|
Operating temp.: |
-20°C ... +90°C |
Protection: |
IP 65 |
Type of Connection: |
Cable or Plug |
Resolution: |
max. 16384 (14 Bit) |
Interface: |
SSI, Parallel or 4..20 mA
|
Supply voltage DC: |
5 V or 10...30 V |
Optional: |
EX approval for hazardous areas 2/22 |
more... |
|
|
|
Standard Type 5852
(Shaft), 5872 (Hollow shaft)
Shaft/Hollow shaft Ø: |
Ø 6/10/12 mm |
Housing diam.: |
Ø 58x66 |
Speed: |
12.000 U/min |
Operating temp.: |
-20°C ... +90°C |
Protection: |
IP 65 |
Type of Connection: |
Cable or Plug |
Resolution: |
max. 16384 (14 Bit) |
Interface: |
Parallel |
Supply voltage DC: |
5 V or 10...30 V |
Optional: |
EX approval for hazardous areas 2/22
Sea-water
resistant |
more... |
|
|
|
Stainless steel 5876
(Hollow shaft) Niro
Hohlwelle Ø: |
Ø 10/12 mm |
Housing diam.: |
Ø 58x41,3 |
Speed: |
6.000 U/min |
Operating temp.: |
-20°C ... +80°C |
Protection: |
IP 66 |
Type of Connection: |
Cable or M12-connect |
Resolution: |
max. 16384 (14 Bit) |
Interface: |
SSI or Parallel |
Supply voltage DC: |
5 V or 10...30 V |
Optional: |
EX approval for hazardous areas 2/22 |
more... |
|
|
|
Sendix absolut 5858
(Shaft) 5878 (Hollow shaft)
Shaft/Hollow shaft Ø: |
Ø 6/10/15 1/4" /3/8" |
Housing diam.: |
Ø 58x50 |
Speed: |
9.000 U/min |
Operating temp.: |
-40°C ... +80°C |
Protection: |
IP 67 |
Type of Connection: |
Cable or Plug |
Resolution: |
max. 65536 (16 Bit) |
Interface: |
Profibus, CANopen or EtherCat
|
Supply voltage DC: |
10...30 V |
Optional: |
EX approval for hazardous areas 2/22
Sea-water
resistant |
more... |
|
|
|
ATEX approved 7031
(Shaft or Hollow shaft)
Shaft/Hollow shaft Ø: |
Ø 12 mm |
Housing diam.: |
Ø 70x94 |
Speed: |
6.000 U/min |
Operating temp.: |
-20°C ... +70°C |
Protection: |
IP 64 |
Type of Connection: |
Cable or Plug |
Resolution: |
max. 16384 (14 Bit) |
Interface: |
SSI, parallel or 4--20 mA
|
Supply voltage DC: |
5 V or 10...30 V |
Optional: |
ATEX
Zone 1,2 and 21,22 |
more... |
Absolute Encoders Multiturn
These characteristics are ideal, for example, in the
following applications:
-
Trains, buses, construction plant, agricultural
vehicles and other mobile equipment
-
Movement of materials, storage, transport and
storage technology
-
Plant engineering & Construction
-
Elevators
-
Gears & motors
- Wind
power
|
Sendix absolut F3663
(Shaft), F3683 (Hollow shaft)
Shaft/Hollow shaft Ø: |
Ø 6/ 1/4" / 8 / 10 mm |
Housing diam.: |
Ø 36x42 |
Speed: |
12.000 U/min |
Operating temp.: |
-30°C ... +90°C |
Protection: |
IP 67 |
Type of Connection: |
Cable |
Resolution: |
17x24 Bit |
Interface: |
SSI, BiSS |
Supply voltage DC: |
5 V or 10...30 V |
Optional: |
EX approval for hazardous areas 2/22 |
more... |
|
|
|
Sendix absolut F3668
(Shaft), F3688 (Hollow shaft)
Shaft/Hollow shaft Ø: |
Ø 6/ 1/4" / 8 / 10 mm |
Housing diam.: |
Ø 36x42 |
Speed: |
12.000 U/min |
Operating temp.: |
-30°C ... +85°C |
Protection: |
IP 67 |
Type of Connection: |
Kabel |
Resolution: |
16 Bit |
Interface: |
CANopen |
Supply voltage DC: |
10...30 V |
Optional: |
EX approval for hazardous areas 2/22 |
more... |
|
|
|
Sendix absolut 5863
(Shaft), 5883 (Hollow shaft)
Shaft/Hollow shaft Ø: |
Ø 6/10/15 1/4" /3/8" |
Housing diam.: |
Ø 58x49,5 |
Speed: |
12.000 U/min |
Operating temp.: |
-40°C ... +90°C |
Protection: |
IP 67 |
Type of Connection: |
Cable or Plug |
Resolution: |
max. 17x12 Bit progr. |
Interface: |
SSI, BISS, + incremental track
(sinus/cosinus or TTL) |
Supply voltage DC: |
10...30 V |
Optional: |
EX approval for hazardous areas 2/22
Sea-water
resistant |
more... |
|
|
|
Multiturn 5862
(Shaft), 5882 (Hollow shaft)
Shaft/Hollow shaft Ø: |
Ø 6/10/12 mm |
Housing diam.: |
Ø 58x66 |
Speed: |
6.000 U/min |
Operating temp.: |
-20°C ... +80°C |
Protection: |
IP 65 |
Type of Connection: |
Cable or Plug |
Resolution: |
max. 13x12 Bit progr. |
Interface: |
SSI, RS 485, AWG-Pr. |
Supply voltage DC: |
10...30 V |
Optional: |
EX approval for hazardous areas 2/22
Incremental Track
Sea-water
resistant |
more... |
|
|
|
Multiturn Fieldbus
Shaft, blind hollow shaft 5860
Shaft/Hollow shaft Ø: |
Ø 6/10 mm |
Housing diam.: |
Ø 60x88 |
Speed: |
6.000 U/min |
Operating temp.: |
-10°C ... +80°C |
Protection: |
IP 65 |
Type of Connection: |
Cable or M12-connect |
Resolution: |
max. 13x12 Bit |
Interface: |
DeviceNet |
Supply voltage DC: |
10...30 V |
Optional: |
EX approval for hazardous areas 2/22
IP 66
Sea-water
resistant |
more... |
|
|
|
Sendix absolut 5868
(Shaft), 5888 (Hollow shaft)
Shaft/Hollow shaft Ø: |
Ø 6/10/15 1/4" /3/8" |
Housing diam.: |
Ø 58x70 |
Speed: |
9.000 U/min |
Operating temp.: |
-40°C ... +80°C |
Protection: |
IP 67 |
Type of Connection: |
Cable or Plug |
Resolution: |
max. 65.536 (16 Bit), scalable
|
Interface: |
CANopen/CANlift, Profibus, EtherCat,
CANopen with incremental track (TTL)
|
Supply voltage DC: |
10...30 V |
Optional: |
EX approval for hazardous areas 2/22
Sea-water
resistant |
more... |
|
|
|
Multiturn programmable
9081
Hollow shaft Ø: |
Ø bis 28 mm |
Housing diam.: |
Ø 90x50 |
Speed: |
6.000 U/min |
Operating temp.: |
-20°C ... +80°C |
Protection: |
IP 66 |
Type of Connection: |
Plug |
Resolution: |
max. 13x12 Bit progr. |
Interface: |
SSI, RS 485, AWG-PR. |
Supply voltage DC: |
5...30 V |
Optional: |
EX approval for hazardous areas 2/22
|
more... |
|
|
|
Multiturn Feldbus 9080
Shaft/Hollow shaft Ø: |
Ø 12/12...28 mm |
Housing diam.: |
Ø 90x60 |
Speed: |
6.000 U/min |
Operating temp.: |
-10°C ... +80°C |
Protection: |
IP 65 |
Type of Connection: |
Cable or M12-connect |
Resolution: |
max. 13x12 Bit |
Interface: |
Profibus, CanOpen, DeviceNet
|
Supply voltage DC: |
5...30 V |
Optional: |
EX approval for hazardous areas 2/22
IP 66 |
more... |
|