Slip ring for wind turbine pitch control hub
Challenge
Conventional brush-type slip ring in the pitch-control hub required quarterly maintenance and failed prematurely in high-humidity coastal sites.
Solution
LTN SC050 maintenance-free slip ring with gold-on-gold contacts and hermetic sealing fitted to hub; Murrplastik UV-rated conduit used for lead-ins.
Maintenance interval extended from 3 months to over 3 years; slip ring failures at coastal site reduced to zero over a 2-year period.