Cable Entry Systems for Control Cabinets and Machines

Murrplastik cable entry frames, plates and grommets route cables into control cabinets and terminal boxes, including cables with connectors already fitted. Strain relief plates and protection conduits complete the cable path. Our application engineers help you choose the right system for your cut-out and cable count.

Murrplastik KDL/C
Murrplastik KDL/C

Cable glands need one hole per cable and force you to cut off and re-terminate moulded connectors. The result is crowded panel walls, long assembly times, leaky entries and strain on the terminals when cables are pulled.

Types of cable entry systems

Split cable entry frames for pre-assembled cables

Splittable frames that let cables pass through with their connectors fitted, so no re-termination is needed. The KDL/C takes up to 48 pre-assembled cables; the KDL/H is a robust zinc die-cast or aluminium version.

Models: KDL/C · KDL/D · KDL/E · KDL/E+ · KDL/H

Cable entry grommets

Grommets fitted around the cable and then inserted into the frame, sealing the entry and providing strain relief. Double and multi-line grommets and AS-i bushings are available.

Models: KDT/X · KDT/ZE

Cable entry plates and membranes

Plates that fit standard connector cut-outs and take many cables through one opening, up to IP66/67 and IP69K on the KDP/Z (with matching cables and screwed). The KDM/F membranes fit metric cut-outs from M16 to M32.

Models: KDP/X · KDP/N · KDP/F · KDP/Z · KDM/F

Strain relief and cable fixing plates

Plates for holding cables and hoses with cable ties, on mounting plates, top-hat rails or C-rails, plus shield clamps for connecting cable shields to earth potential.

Models: Type ZL · ZL-AH · ZL-MH · ZL-AM · KAF · Type SK

Cable protection conduits

Flexible corrugated conduits for bundling and protecting cables on machines. The EWT versions are slit and can be opened and closed at any time, for pre-assembled cables and retrofits.

Models: EWX · EWL-PA · EWL-PAB · EWT-PA · EWT-PP

What to specify

ParameterWhat to check
Cables with or without connectorsFor pre-assembled cables use a split frame (KDL series) with grommets. For cables without connectors, a cable entry plate or membrane is usually quicker.
Cut-out sizeMost frames and plates fit standard 24-pin or 16-pin industrial connector cut-outs, so no special machining is needed. The KDM/F fits metric M16 to M32 holes.
Number and diameter of cablesCount the cables and list their diameters. Frames and plates pack many cables into one cut-out; grommets are chosen per cable diameter.
Protection classMatch the enclosure: IP54 on the KDL/C, IP65 on the KDP/X, KDP/N and KDP/F, up to IP69K on the KDP/Z for washdown areas. The rating depends on the right grommets and cables being fitted.
Strain reliefDecide whether strain relief is needed at the entry itself (integrated on the KDL/C, KDL/D and KDL/H) or inside the cabinet on a ZL or KAF plate.
Material and environmentPlastic frames for most panels; metal frames (KDL/H) for heavy machinery. Check temperature and UV exposure for outdoor installations.
Request a QuoteSend us your application details and an application engineer will recommend a suitable model.

23 models in our range

Cable entry plates 12

Where they're used

Control cabinets

Many cables through one cut-out instead of a row of glands.

Pre-assembled drive & servo cables

Cable entry without cutting off moulded connectors.

Machine and robot panels

High-density, strain-relieved entry on OEM machines.

Washdown areas

Sealed cable entry in food and pharma plants.

Terminal & junction boxes

Tool-free entry through metric cut-outs.

Cable routing on machines

Protection conduits and strain relief plates along the cable path.

Common questions

Why use a split cable entry system instead of cable glands?

A split frame opens around the cable, so cables with moulded connectors can be fed into the cabinet without cutting them off and re-terminating. It also takes many cables through one standard cut-out, which saves space on the panel wall and assembly time.

How many cables fit in one cable entry frame?

It depends on the frame and the cable diameters. The KDL/C and KDL/H take up to 48 cables in one frame. Send us your cable list and we will work out the frame and grommets.

Do I need special cut-outs in the cabinet?

Usually not. Most Murrplastik frames and plates fit standard cut-outs for 24-pin and 16-pin industrial connectors, and the KDM/F membranes fit metric M16 to M32 holes.

Which cable entry is suitable for washdown areas?

The KDP/Z cable entry plate reaches IP66/67 and IP69K when fitted with matching cables and screwed in place, which suits washdown areas in food and pharma plants.

What is a strain relief plate used for?

It holds cables and hoses in place with cable ties, so pulling on a cable does not load the terminals or connectors. The ZL plates are screwed in place, the KAF snaps onto a 35 mm top-hat rail or C-rail.

Established
1994
Quality system
ISO 9001:2015
Offices
8 across India
Support
In-house application engineers
LMWACE DesignersABBBobstELGI EquipmentWindsor MachinesKloeckner DesmaMETAFLEXMRF TyresWipro PariVideojetLMWACE DesignersABBBobstELGI EquipmentWindsor MachinesKloeckner DesmaMETAFLEXMRF TyresWipro PariVideojet

Planning the cable entry for a panel?

Send us the cable list with diameters, whether connectors are fitted, the cut-out size and the protection class you need. We'll recommend frames, grommets or plates.